The Elcometer 106 Adhesion Tester is easy to operate and fully portable, and provides a numerical value for adhesion. Applications include paint or plasma spray on bridge decking, coatings on steel, aluminium, concrete etc.
- Supplied in a carry case - ideal for site tests
- Hand operated - no need for a power supply
- Includes a cutter for EN13144 and ISO 4624 tests
Test Method
A test dolly is bonded to the coating using an adhesive. The 106 houses a spring arrangement which applies a lift force to the dolly as the tension is increased.
When the coating is pulled off the surface, an indicator on the scale shows the numerical value of adhesion expressed in terms of the force per unit area required to remove the dolly.
Inspection of the dolly face is required to determine the failure mode.
To increase sensitivity at low values or for uneven surfaces, a 40mm (1.52”) dolly is available. When using the 40mm (1.52”) dolly, divide the scale reading by 4.
Technical Specification:
Part Number |
Description |
Range |
MPa (N/mm2) |
kg/cm2 |
psi |
F106----5 |
Elcometer 106 Adhesion Tester - Scale 5 |
0 - 0.2 |
0 - 2 |
0 - 30 |
F106----1 |
Elcometer 106 Adhesion Tester - Scale 1 |
0 - 3.5 |
0 - 35 |
0 - 500 |
F106----2 |
Elcometer 106 Adhesion Tester - Scale 2 |
0 - 7.0 |
0 - 70 |
0 - 1000 |
F106----3 |
Elcometer 106 Adhesion Tester - Scale 3 |
0 - 15 |
0 - 150 |
0 - 2000 |
F106----4 |
Elcometer 106 Adhesion Tester - Scale 4 |
0 -22 |
0 - 220 |
0 - 3200 |
Dimensions |
Scales 1, 2, 5: 152 x 76mm (6 x 3”) Scales 3 and 4: 150mm |
Dolly Diameter |
20mm (0.76”) |
Dolly Area |
314mm² (0.49 sq inch) |
Gross weight of Kit |
Scale 1, 2 and 5: 2.1kg (4.7lb) Scale 3: 3.4kg (7.5lb) Scale 4: 3.6kg (8.0lb) |
Certificate available |
Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability. |
Packing List |
Elcometer 106 Pull Off Adhesion Tester, pack of 20 dollies, Araldite adhesive, base support ring, magnetic dolly clamp, dolly cutter, ratchet spanner (scale 3 & 4 only), carry case and operating instructions |
Can be used in accordance with:
AS 1580.408.5, ASTM D 4541, AS/NZS 1580.408.5, EN 13144, EN 24624, ISO 4624, ISO 16276-1, JIS K 5600-5-7, NF T30-062, NF T30-606
Standards in grey have been superseded but are still recognised in some industries.
Accessories:
T1062895-10 |
Spare Dollies 20mm (0.76”) Diameter (Pack of 10) |
T1062895- |
Spare Dollies 20mm (0.76”) Diameter (Pack of 100) |
T1062914- |
Large Dollies 40mm (1.52 Diameter (Pack of 5) |
T1062915- |
Large Base Ring for 40mm (1.52")Dollies |
T99912906 |
Araldite Epoxy Adhesive |
T99914009 |
20mm (0.76") Dolly Cutter |
Download Full Catalog |