Download Full Catalog
Product Description :
These reusable precision stainless steel combs are made to be long lasting and are supplied with either Metric or Imperial measurements.
Four separate thickness ranges are available up to a maximum of 1270µm / 50mils and are manufactured to an accuracy of 5% or 2.5µm (0.01mil), whichever is the greater.
Each comb has 10 measurement steps (teeth).
Using a wet film comb
Place a comb perpendicular to and touching the substrate. Hold the comb in position and wait a few seconds until the teeth are wet. Remove the comb from the film. The wet film thickness lies between the biggest value ‘coated’ or ‘wet’ tooth and the smallest value ‘uncoated’ or ‘dry’ tooth.
Technical Specification :
METRIC COMBS |
Part Number |
Range
|
Measurement Steps
|
B11529455M |
20 – 325µm |
20, 35, 50, 75, 100, 125, 175, 225, 375, 325µm |
B11529456M |
50 – 450µm |
50, 75, 100, 150, 200, 250, 300, 350, 400, 450µm |
B11529457M |
50 – 750µm |
50, 100, 150, 200, 250, 350, 450, 550, 650, 750µm |
B11529458M |
125 – 1250µm |
125, 250, 375, 500, 625, 750, 875, 1000, 1125, 1250µm |
B1152959WM |
- |
Set of 4 Wet Film Combs |
Certificate available |
Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory. |
IMPERIAL COMBS |
Part Number |
Range
|
Measurement Steps
|
B11529451E |
1 – 13mils |
1, 1.5, 2, 3, 4, 5, 7, 9, 11, 13mils |
B11529452E |
2 – 18mils |
2, 3, 4, 6, 8, 10, 12, 14, 16, 18mils |
B11529453E |
2 – 30mils |
2, 4, 6, 8, 10†, 10†, 15, 20, 25, 30mils |
B11529454E |
5 – 50mils |
5, 10, 15, 20, 25, 30, 35, 40, 45, 50mils |
B1152959WE |
- |
Set of 4 Wet Film Combs |
Certificate available |
Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory. |
† Two 10mil values, one on each edge of the comb
Can be used in accordance with:
ASTM D 4414-A, AS/NZS 1580.107.3, BS 3900-C5-7B, ISO 2808-1A, ISO 2808-7B, JIS K 5600-1-7, NF T30-125,
US NAVY PPI 63101-000, US NAVY NSI 009-32
Standards in grey have been superseded but are still recognised in some industries.
Download Full Catalog
|