Download Full Catalog
Product Description:
This simple to use gauge is ideal for evaluating the resistance of a coating to impact (elongation, cracking or peeling).
There are two test methods: either a weight with a hemispherical punch attached falls on a coated metal sheet or a weight falls on to a hemispherical punch which is resting on the coated metal sheet.
The Elcometer 1615 Impact Tester comes as one universal assembly with the option of six different kits providing the functionality for various testing methods.
The test specimen is fixed into position by the quick release clamp. The weight is lifted to the predetermined height and can be set by the adjustable collar device. The weight is then released and the resulting deformation is observed.
The base unit is common to all tests. Simply select the appropriate kit to meet your requirements.
- Heavy-duty passivated base plate and anodised arm for long life
- Graduated tube with engraved markings
- Quick, safe weight release mechanism
- Integrated bubble level to ensure the tester is perpendicular for accurate results
- Stop collar with 10 settings between 2mm and 15mm (0.08 and 0.60") to change the depth of impact when working in accordance with ISO Standards, supplied with Kits A, D and F
- Easy fix sample clamp - the test sample can be sercured or released by a simple twist of the clamp handle supplied with Kits A, D and F
- Magnifier x 10
 |
The tube has clearly engraved, graduated markings in both kg-c and lb-inch to ensure accuracy and a quick, safe weight release mechanism which holds the weight safely and allows a smooth release.
Tube height: 1000mm (39") |
 |
The stop collar, supplied with Kits A, D and F or as an optional accessory, allows the penetration depth to be limited. By rotating the stop collar, the user can selet the depth required between 2-15mm (0.08 - 0.06").
Values: 2,3,4,5,6,7,8,9,10 and 15mm
(0.08, 0.12, 0.16, 0.20, 0.24, 0.28, 0.31, 0.35, 0.39 and 0.60")
Each Impact Tester is supplied with an integrated bubble level ensuring accurate setup prior to anytest. |
.jpg) |
The Elcometer 1615 Variable Impact Testers are designed to meet a wide range of National and International Standards. Simply select the appropriate kit and attach the punch, die and accessories to the base unit. Interchangeable die - enables the user to match the die to the size of the relevant punch to conform to the required Standard or method.
The optional easy to fix sample clamp enables the user to quickly |
Technical Specification:
Part Number |
Description |
K0001615M201 |
Elcometer 1615 Impact Tester Universal Base Unit and Tube |
Weight |
10.6kg (23.34lb) |
Dimensions |
1460 x 200 x 165mm (57.5 x 8.0 x 6.5") |
Certificate available |
Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory. |
Packing List |
Elcometer 1615 Impact Tester with passivated base, integrated bubble leveller, graduated tube, collar release mechanism and operating instructions |
KT001615KITA |
Elcometer 1615 Kit A to meet ISO 6272:1993 Standard |
|
KT001615KITB |
Elcometer 1615 Kit B to meet ISO 6272 Part 2:2002 Standard |
|
KT001615KITC |
Elcometer 1615 Kit C to meet ASTM D2794 Method 2, BS6496:1984, EN 12206-1 Standards |
|
KT001615KITD |
Elcometer 1615 Kit D to meet ISO 6272 Part 1:2002, BS EN ISO 6272-1:2004 Standards |
|
KT001615KITE |
Elcometer 1615 Kit E to meet NF T30-017:1989 Standard |
|
KT001615KITF |
Elcometer 1615 Kit F to meet ISO 6272:1993, ISO 6272- 2:2002 Standards |
|
Packing List |
Kit A: Sample damp, 27mm (1.06”) die,1kg (2.2lb) falling weight with a 20mm (0.79”), punch, stop collar, 2 x hexagonal wrench and operating instructions |
|
Kit B: Indenter with 15.9mm (0.6”) punch, die 16.3mm (0.64”), falling 1kg (2.2lb) weight,
hexagonal wrench and operating instructions |
|
Kit C: Indenter with 15.9mm (0.6”) punch, 2lb (0.91kg) falling weight and operating instructions |
|
Kit D: 1kg (2.2lb) falling weight with 20mm (0.79”) punch, 27mm (1.06”) die, stop collar,
hexagonal wrench and operating instructions |
|
Kit E: 400g (0.88lb) falling weight with a 23mm (0.9”) punch, 22mm (0.87”) die, sample clamp, hexagonal wrench and operating instructions |
|
Kit F: Sample clamp, stop collar, 27mm (1.06”) die,1kg falling indenter with a 20mm (0.79”)
punch, indenter with 15.9mm (0.6”) punch,12.7mm (0.5”) punch, 16.3mm (0.6”) die, falling
1kg weight, 2 x hexagonal wrench and operating instructions |
Can be used in accordance with:
ASTM D 2794, ASTM D 5420, AS/NZS 1580.406.1, BS 6496:1984, BS 3900-E13, ECCA T5, EN 12206-1:2004, EN 13523-5, ISO 6272:1993, ISO 6272-1, ISO 6272-2, JIS K 5600-5-3:1999, NFT30-017:1989
Standards in grey have been superseded but are still recognised in some industries.
Accessories:
KT001615KITA |
Elcometer 1615 Kit A to meet ISO 6272:1993 Standard |
KT001615KITB |
Elcometer 1615 Kit B to meet ISO 6272 Part 2:2002 Standard |
KT001615KITC |
Elcometer 1615 Kit C to meet ASTM D2794 Method 2, BS6496:1984, EN 12206-1 Standards |
KT001615KITD |
Elcometer 1615 Kit D to meet ISO 6272 Part 1:2002, BS EN ISO 6272-1:2004 Standards |
KT001615KITE |
Elcometer 1615 Kit E to meet NF T30-017:1989 Standard |
KT001615KITF |
Elcometer 1615 Kit F to meet ISO 6272:1993, ISO 6272- 2:2002 Standards |
KT001615N201 |
Additional 1kg (2.2lb) Falling Weight, 24.6mm (0.97") Diameter |
KT001615N221 |
Additional 1kg (2.2lb) Falling Weight, 25.0mm (0.98 ) Diameter |
KT001615N215 |
12.7mm (0.5") Diameter Punch* |
KT001615N205 |
15.9mm (0.6") Diameter Punch* |
KT001615N206 |
20mm (0.79") Diameter Punch* |
KT001615N207 |
23mm (0.9") Diameter Punch* |
KT001615N208 |
Stop Ring Collar |
KT001615N209 |
Sample Clamp Mechanism |
KT001615N210 |
Weight Release Mechanism |
KT001615N211 |
Replacement Graduated Tube |
KT001615N212 |
16.3mm (0.64") Die |
KT001615N213 |
22mm (0.67") Die |
KT001615N214 |
27mm (1.06") Die |
Download Full Catalog
|