Back to S
Series Products
Atomic Absorption Spectrophotometer, Double Beam Atomic Absorption Spectrophotometer, Single
Beam Atomic Absorption Spectrophotometer, NIR
Spectrophotometer, Spectrofluorometer,
Bio
- Spectrophotometer, Double
Beam UV-VIS spectrophotometer, Single
Beam UV-VIS Spectrophotometer, UV-VIS
Spectrophotometer, Scanning
Visible Spectrophotometer, Visible
Spectrophotometer, Fluorometer,
Colorimeter
Spectroscopy - Colorimeter
|
Stable, Direct Readout of Absorbance |
Compact & Easy to operate |
Rugged, Sturdy & Reliable |
Thumb Wheel Selection of Filters |
Pre-focussed Light Source |
Long Life Photo Diode Detector |
Only 1 ml of Sample need |
Usable for Disposable cells |
Colorimeter
Application In determination of concentration of constituents in
- Clinical, Pharmaceutical, Food, Beverage & Water Analysis
- Analytical & Agricultural Chemistry
- Metallurgy
Colorimeter Operation Principle
When light, of comparatively narrow range of wavelengths in the
visible spectrum,is passed through a homogeneous medium, a part
of the light is reflected, a part is absorbed within the medium
and remainder is transmitted. The intensity of the light emerging
from the medium decreases exponentially as the concentration and
thickness of the absorbing medium increase arithmetically, as per
laws of Beer & Lambert. If the container and the thickness of
the medium is kept constant, the intensity of light emerging out
of the medium, with respect to the incident light, is directly proportional
to the concentration of the medium.
With this principle, in colorimetry, the concentration of a coloured
solution is determined by measurement of relative absorption of
light with respect to a solution of known concentration
This COLORIMETER CL 157 is a table top, ergonomically engineered
instrument with its components and modules inside and controls,
readouts, etc., on the panels outside laid out for ease of operation
and maintainability
Light from pre-focussed tungsten filament lamp is focussed by a
lens system on to a photocell through filters, of discrete bands
of overlapping wavelengths covering the visible spectrum, selectable
by a filter wheel, and a test tube/cell containing solution under
investigation. The electrical output of a photo diode is processed
and the value of absorbance displayed on the readout
The instrument is incorporated with facilities to adjust the intensity
of light, appropriate for the expected concentration of the sample,
by aperture control and prevention of exposure of photocell to the
light, when measurement is not being carried out, by use of a shutter.
Photometric |
Range |
-0.1 to 1.99 Abs |
Repeatability |
± 0.01 Abs |
Stability |
± 0.01 Abs in 8 h |
|
Light Source |
Tungsten Lamp |
|
Filters (8) |
Peak Transmission at 450, 470, 490, 520, 540, 570, 600 &
670 nm |
|
Shutter |
To prevent the detector from continuous exposure to light |
|
|
Photo diode |
|
Readout |
2½ Digit 7 segment LED display of 12.7mm height |
|
Power Requirement |
230 V ± 10%, 50 Hz, 1 , Max. 20VA |
|
Physical Dimensions |
Size (WxDxH) in mm |
270 x 180 x 110 |
Weight in Kg. |
Approx. 3.0 |
|
Accessories Supplied |
With Instrument |
Matched 3 mL test tubes, holder for 10mm path length glass
cuvettes disposable cells |
At Extra cost |
Glass cuvettes & disposable cells |
Specifications subject to change due to continuous
development
|
|
|