Back to S
Series Products
Atomic Absorption Spectrophotometer, Double
Beam Atomic Absorption Spectrophotometer, Single
Beam Atomic Absorption Spectrophotometer, NIR
Spectrophotometer, Spectrofluorometer,
Bio
- Spectrophotometer, Double
Beam UV-VIS spectrophotometer, Single
Beam UV-VIS Spectrophotometer, UV-VIS
Spectrophotometer, Scanning
Visible Spectrophotometer, Visible
Spectrophotometer, Fluorometer,
Colorimeter
Spectroscopy - Atomic Absorption Spectrophotometer
|
Microprocessor based, user friendly,
menu driven, with printer interface |
Optional PC Compatibility with RS
232C Interface and MS Windows® based Software for Data Acquisition,
Processing, Storage, Retrieval & Interpretation of Data |
Modes of operation include Absorbance,
Concentration, Standard Addition & Emission |
Continuous Source Background Correction |
Quick Change and Easy alignment
of Hollow Cathode Lamps with standby Warm-up facility |
Precise vertical, lateral and rotational
alignment of Titanium Burner |
Optimal parameters storable in built-in
memory |
Self diagnostic |
For analysis in various metallic constituents in
Soil, Fertilizers, Micro Nutrients, Plants, Pesticides, Foods,
Water, Biological matter, Metallurgy, Plating, Coal, Petrochemicals,
Glass, Steel, etc. |
Spectral
|
Range |
190 to 900 nm
|
Accuracy |
± 0.5 nm
|
Bandwidth |
0.15 to 3.0 nm variable in steps of 0.15 nm
|
|
Photometric
|
Range |
0 to 2 Abs
|
Accuracy |
± 0.01 Abs at 1 Abs
|
Integration Time |
0.04 to 99 Sec |
|
Light Source |
Hollow Cathode Lamp (HCL)* |
|
Background correction |
Deuterium Lamp (D2)*
|
|
Burner |
Titanium Construction Premix, Laminar
flow, 100 mm
|
|
Fuel |
Acetylene (C2H2)
|
|
Oxidant |
Air/Nitrous Oxide (N2O)
|
|
Flow Control |
Integral gas control system with panel flow meters
|
|
Nebulizer |
Pneumatic, with 90% Platinum, & 10% Iridium
alloy Capillary*
|
Sample Feed Rate |
3 to 8 mL/min (Adjustable) |
|
Monochromator |
Czerny Turner 300 mm with 1200 lines/mm Holographic
diffraction grating & Hard coated optics
|
|
Slits |
Bilateral continuously variable of 0.15 to 3.0nm
spectral bandwidth
|
|
Detector |
Wide Range Photomultiplier tube (PMT)
|
|
Readout |
24x2 Dot matrix LCD panel with backlight of 2.70
x 5.5mm character size
|
|
Power
Supply
|
HC Lamp |
0 to 30 mA, modulated
|
D2 |
15 to 300 mA, modulated
|
PMT |
-200 to -1000 V
|
|
Power requirement |
230 V ± 10%, 50 Hz, 1 , Max. 200 VA
|
|
Physical dimensions
|
Size (W x D x H) in mm |
700 x 490 x 330
|
Weight in kg |
Approx. 50
|
|
Accessories supplied
|
With instrument
|
Burner - 100 mm (Air - C2H2)
Nebulizer - with Pt-lr capillary |
At Extra cost |
HC Lamps of desired elements, Background correction - with D2
lamp, Burner - 50 mm for N2O - C2H2,
Hydride/Vapour Generator, Compressor, Printer, PC & Software
|